Products Specification:
◎H8C load cells are available in the capacities 1Klb to 20Klb and 0.5t to 10t.
◎Alloy steel,sealed by adhesive inside,oil-proof,waterproof and anti-corrosion, suitable for all kinds of environment.
◎Single shear beam, easy for installation,suitable for electronic platform scales,hopper scales and other electronic weighing devices.
◎Safe and anti-explosive product,can be used in atrocious environment and hazardous areas.
Features:
◎Capacity:1Klb to 20Klb and 0.5t to 10t.
◎High accuracy.
◎Alloy steel construction.
◎Low profile.
◎OIML Certificate No.:R60/2000-CN-00.02
◎Germany PTB Certificate No.:D09-03.19 2.Revision
◎NTEP Certificate No.:CC 07-012
Outline Dimension mm(inch)
Capacity | L | L1 | L2 | L3 | L4 | H | H1 | W | W1 | D | d | M |
0.5t,1~2t
1~4K, 5KSE |
130 | 15.8 | 25.4 | 76.2 | 54.2 | 31.8 | 15.8 | 31.8 | 34 | 13.5 | 13.5 | M12×1.75
1/2 -20UNF |
-5.12 | -0.62 | -1 | -3 | -2.13 | -1.25 | -0.62 | -1.25 | -1.34 | -0.53 | -0.53 | ||
2.5~5t
5~10K |
171.5 | 19.1 | 38.1 | 95.3 | 77.2 | 38.1 | 18.8 | 38.1 | 40 | 19.8 | 19.8 | M18×1.5
3/4 -16UNF |
-6.75 | -0.75 | -1.5 | -3.75 | -3.04 | -1.5 | -0.74 | -1.5 | -1.57 | -0.78 | -0.78 | ||
10t,20K | 222.3 | 25.4 | 50.8 | 120.7 | 101.6 | 50.8 | 25.4 | 50.8 | 52.4 | 26.92 | 26 | M24×2
1 -12UNF |
-8.75 | -1 | -2 | -4.75 | -4 | -2 | -1 | -2 | -2.06 | -1.06 | -1.02 |
Specifications:
Capacity | t | 0. 5/1/1.5/2/2.5/3/5/10 | ||||
Klb | 1/1.5/2/2.5/3/4/5/5KSE/7.5/10/15/20 | |||||
Accuracy class | C2 | C3 | C4 | A5M | B10M | |
Approval | OIML R60 C3 | III 5000 multiford | III L 10000 multiford | |||
Maximum number of verification intervals | n max | 2000 | 3000 | 4000 | 5000 | 10000 |
Minimum load cell verification interval | v min | Emax/5000 | Emax /10000 | Emax /14000 | Emax/15000 | Emax/10000 |
Combined error | (%FS) | ≤±0.030 | ≤±0.020 | ≤±0.018 | ≤±0.026 | ≤±0.050 |
Creep | %FS/30min | ≤±0.024 | ≤±0.016 | ≤±0.012 | ≤±0.017 | ≤±0.040 |
Temperature effect on sensitivity | (%FS/10℃) | ≤±0.017 | ≤±0.011 | ≤±0.009 | ≤±0.013 | ≤±0.040 |
Temperature effect on zero | (%FS/10℃) | ≤±0.023 | ≤±0.015 | ≤±0.010 | ≤±0.014 | ≤±0.020 |
Output sensitivity | (mv/v) | 2.0 ±0.002 | 3.0±0.003 | |||
Input resistance | (Ω) | 350±3.5 | ||||
Output resistance | (Ω) | 350±3.5 | ||||
Insulation resistance | (MΩ) | ≥ 5000(100VDC) | ||||
Zero balance | (%FS) | 1 | ||||
Temperature,compensated | (℃) | -10~+40 | ||||
Temperature,allowed | (℃) | -35~+70 | ||||
Excitation,Recommended | (V) | 5~12(DC) | ||||
Excitation,Max | (V) | 18(DC) | ||||
Safe overload | (%FS) | 150 | ||||
Ultimate overload | (%FS) | 300 |
Note:Output sensitivity of S1 type is 2.0 ±0.002