- Home
- Our Products
- Load Cell
- Digital Load Cell
- Column Digital Load Cell for Check Weigher Digital Load Cell for Hopper Weight Scales
Column Digital Load Cell for Check Weigher Digital Load Cell for Hopper Weight Scales
- General Details
- Order Inquiry
General Details
Column Digital Load Cell for Check Weigher Digital Load Cell for Hopper Weight Scales
Dimensions: Unit: mm
Cap./Size | A | B | C | D | E | F | G | H | SR |
10~30t | 150 | 40 | 34.7 | 38 | 82 | 41.7 | 82 | 8 | 150 |
40~60t | 170 | 53 | 43 | 47 | 95 | 53 | 88 | 10 | 200 |
Product Characteristics:
LC404D digital load cell. Digital output signal (RS-485/4-Wire). Normal load 10~100t. Self-restoring rocker pin. Easy to install. Hermetically sealed. Produce according OIML R60 to 3000d. Over voltage protection.
Technical Parameter:
Rated Load: | 10/20/30/40/50/60t | Insulation Resistance: | ≥5000MΩ |
Rated Output: | 1000000 | Operating Temp. Range: | -30~+70℃ |
Baud Rate:: | 9600 Baud | Maximum Safe Over Load: | 150%F.S |
Measuring Rate: | 80/sec | Ultimate Over Load: | 250%F.S |
Communication Mode: | RS485/4-wire | Recommend Excitation Vol.: | 10~12V DC |
Combined Error: | ±0.03% F.S | Maximum Excitation Vol.: | 15V DC |
Creep Error(30min): | ±0.02% F.S | Sealing Class: | IP67/IP68 |
Zero Balance: | ±1% F.S | Element Material: | Alloy /Stainless Steel |
Temp. Effect On Zero: | ±0.017% F.S/10℃ | Cable: | Length=12m~16m |
Temp. Effect On Span: | ±0.017% F.S/10℃ | Citation: | GB/T7551-2008/ OIML R60 |
Order Inquiry
Contact us by email sales@goldshinechina.com or WhatsAPP 008615869588089