- Home
- Our Products
- Load Cell
- Column Load Cell
- Cylindrical Bridge Column Type Load Cells sensor
Cylindrical Bridge Column Type Load Cells sensor
Cylindrical Bridge Column Type Load Cells sensor
GOldshine |
LC429 |
Compression Load Cell |
Dimension: in mm
Size | Capacity | ||||||||||
500kg | 1t | 2t | 3t | 5t | 10t | 20t | 50t | 100t | 200t | 300t | |
A | 40.0 | 62.0 | 62.0 | 62.0 | 60.0 | 60.0 | 90.0 | 115.0 | 166.0 | 236.0 | 236.0 |
B | 35.0 | 55.0 | 55.0 | 55.0 | 36.0 | 36.0 | 68.0 | 109.0 | 141.0 | 190.0 | 195.0 |
C | 10.0 | 18.0 | 18.0 | 18.0 | 18.0 | 18.0 | 43.0 | 80.0 | 85.0 | 120.0 | 120.0 |
D | 50.0 | 74.0 | 70.0 | 70.0 | 70.0 | 80.0 | 80.0 | 110.0 | 110.0 | 120.0 | 120.0 |
E | 3.0 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 | 5.0 | 7.0 | 7.0 | 7.0 | 7.0 |
Hollow structure, alloy steel material. Low profile, strong shock resistance,good machining technics, strict production flow controlled. Used to control rolling force in metallurgy industry process control devices and other measuring equipment, as well as used in architecture industry.
Technical Parameter:
Rated Load: | 0.5/1/2/3/5/10/20/50/100/200/300t | ||
Sensitivity: | (1.0±0.1%) mV/V | Operating Temp. Range: | -20~+60℃ |
Hysteresis: | ±0.3% F.S | Compensated Temp: | -10~+50℃ |
Combined Error: | ±0.03% F.S | Max. Safe Over Load: | 150%F.S |
Creep Error(30min): | ±0.1% F.S | Ultimate Over Load: | 250%F.S |
Zero Balance: | ±2% F.S | Recommend Excitation: | 10~12V DC |
Temp. Effect On Zero: | ±0.01% F.S/10℃ | Maximum Excitation: | 15V DC |
Temp. Effect On Span: | ±0.05% F.S/10℃ | Sealing Class: | IP67/IP68 |
Input Resistance: | 385±10Ω | Element Material: | -A: Alloy Steel,-SS: Stainless Steel |
Output Resistance: | 350±3Ω | Cable: | Length=12m(0.5~10t),18m(30~300t) |
Insulation Resistance: | ≥5000MΩ | Citation: | GB/T7551-2008/ OIML R60 |
Mode Of Connection: | Red(Input+),Black(Input-),Green(Output+),White(Output-) |