- Home
- Our Products
- Load Cell
- Wireless load cell
- load cell with display Self-Indicating Load Links
load cell with display Self-Indicating Load Links
load cell with display Self-Indicating Load Links
LC221W | |
Dillon EDJunior Digital Dynamometers |
Dimension:
Cap./Size | L | L1 | L2 | L3 | B | B1 | B2 | M | W | W1 | W2 | φ |
1~5t | 228 | 25 | 73 | 216 | 55 | 84 | 29 | 5 | 45 | 26 | 18 | 27 |
7.5~10t | 281 | 32 | 86 | 249 | 60 | 98 | 34 | 6 | 60 | 38 | 23 | 33 |
15~20t | 331 | 40 | 110 | 300 | 85 | 125 | 50 | 8 | 75 | 55 | 40 | 44 |
Product Characteristics:
LC221W series is special wireless load cell for crane scale. Element material made of alloy steel or stainless steel according to customer’s requirement. High precision, strong overload protection capacity and anti-deflective loading. The load cell with special hook and ring, easy installation.
Circuit Diagram:
Technical Parameter:
Rated Load: | 1t/2t/3t/5t/10t/20t | Input Resistance: | 750±5Ω |
Wireless Frequency: | 430~485MHz | Output Resistance: | 702±2Ω |
Wireless Distance: | Min:800m(default) | Insulation Resistance: | ≥5000MΩ |
A/D Conversion Rate: | ≥50 times/seconds | Operating Temp. Range | -30~+70℃ |
Battery Life: | ≥50 hours | Max.Safe Over Load: | 120%F.S |
Sensitivity: | (1.5±0.1%) m V/V | Ultimate Over Load: | 200%F.S |
Combined Error: | ±0.02% F.S | Recommend Excitation: | 10~12V DC |
Creep Error(30min): | ±0.02% F.S | Maximum Excitation: | 15V DC |
Zero Balance: | ±1% F.S | Sealing Class: | IP67 |
Temp. Effect On Zero: | ±0.02% F.S/10℃ | Element Material: | Alloy /Stainless Steel |
Temp. Effect On Span: | ±0.02% F.S/10℃ | Citation: | GB/T7551-2008/OIML R60 |
Notice:
Do not use the wireless load cell in explosive and unsafe place. The wireless range will be effective when in different weather, the load cell with the indicator in different place, orientation or obstruct from .For charge :according to Li-ion battery. Do not excess discharge.