- Home
- Our Products
- Load Cell
- Tension Load Cell
- pull crane load cell 1ton-100 ton
pull crane load cell 1ton-100 ton
pull crane load cell 1ton-100 ton
LC211 | |
Load Cell For Crane Scale |
Dimension:Unit: mm
Cap.(T) | L | L1 | H | H1 | W | W1 | D | D1 | D2 | D3 | D4 | M |
5 | 100 | 62 | 197 | 65 | 34 | 22 | 90 | 25 | 144 | Φ20 | Φ26 | M8 |
7.5 | 100 | 62 | 228 | 91 | 40 | 32 | 90 | 30 | 165 | Φ26 | Φ36 | M8 |
12.5 | 124 | 80 | 260 | 91 | 50 | 32 | 112 | 30 | 197 | Φ26 | Φ36 | M8 |
20~25 | 180 | 120 | 340 | 120 | 80 | 56 | 160 | 50 | 230 | Φ40 | Φ50 | M10 |
Application:
Special load cell for crane scale elastomer use integral alloy steel, high precision, strong overload protection capability and anti-deflective loading. With special ring and hook, easy to install.
Technical Parameter:
Rated Load | 5-25t | Insulation Impedance | ≥5000MΩ |
Sensitivity | 2.0000±0.001mV/V | Safe Overload | 150%F.S |
Total Error | ±0.02%F.S | Ultimate Overload | 200%F.S |
Creep(30minutes) | ±0.02%F.S | Operating Temp. Range | (-30~+70)℃ |
Recommended Excitation Vol. | 5V~12V(AC or DC) | Compensated Temp. Range | (-20~+60)℃ |
Maximum Excitation Vol. | 15V(AC or DC) | Temp. Effect On Load | ±0.02%F.S/10℃ |
Zero Balance | ±1%F.S | Temp. Effect On Zero | ±0.02%F.S/10℃ |
Input Impedance | 380±5Ω | Construction | Alloy Steel |
Output Impedance | 350±2Ω | Protection Class | IP67&IP68 |