- Home
- Our Products
- Load Cell
- Compression Load Cell
- Train Weighing Scales Load Cell Rail Weighing Scales Load Cell for Railway Scale
Train Weighing Scales Load Cell Rail Weighing Scales Load Cell for Railway Scale
- General Details
- Order Inquiry
General Details
Train Weighing Scales Load Cell Rail Weighing Scales Load Cell for Railway Scale
Dimension:
Cap.(t) | L1 | L2 | L3 | B1 | B2 | B3 | H1 | D | Rail model(Kg/m) |
2 | 362 | 320 | 160 | 160 | 120 | 32 | 80.5 | Φ13 | 11 |
5~10 | 382 | 286 | 168 | 135 | 90 | 37 | 91 | Φ17 | 15 |
5~10 | 382 | 286 | 168 | 135 | 90 | 40 | 90 | Φ17 | 18 |
10~15 | 382 | 286 | 168 | 200 | 150 | 51 | 107 | Φ22 | 24 |
5~50 | 402 | 305 | 185 | 220 | 170 | 68 | 134 | Φ22 | 38 |
10~50 | 402 | 305 | 185 | 220 | 170 | 70 | 140 | Φ22 | 43 |
20~60 | 502 | 425 | 280 | 220 | 160 | 70 | 152 | Φ26 | 50 |
40~60 | 452 | 350 | 200 | 260 | 200 | 108 | 150 | Φ28 | Qu100 |
50~60 | 452 | 350 | 200 | 280 | 200 | 129 | 170 | Φ28 | Qu100 |
Technical Parameter:
Rated Load | 10-30t | Insulation Impedance | ≥5000MΩ |
Sensitivity | 2.0000±0.001mV/V | Safe Overload | 150%F.S |
Total Error | ±0.05%F.S | Ultimate Overload | 200%F.S |
Creep(30minutes) | ±0.02%F.S | Operating Temp.Range | (-30~+70)℃ |
Recommended Excitation Vol. | 5V~18V(AC or DC) | Compensated Temp.Range | (-20~+60)℃ |
Maximum Excitation Vol. | 24V(AC or DC) | Temp. Effect On Load | ±0.05%F.S/10℃ |
Zero Balance | ±1%F.S | Temp. Effect On Zero | ±0.02%F.S/10℃ |
Input Impedance | 775±5Ω | Construction | Alloy /Stainless Steel |
Output Impedance | 700±2Ω | Protection Class | IP67&IP68 |
Order Inquiry
Contact us by email sales@goldshinechina.com or WhatsAPP 008615869588089