Features:
◆B8D load cells are available in the capacities 250lb to 20Klb and 0.5t to 5t.
◆Strainless steel construction,potted by adhesive inside. oil-proof,waterproof and anti-corrosive gas and medium making it suitable for all kinds of environments.
◆Single shear beam,easy for installation, suitable for electronic truck scales,automobile testing facilities,hopper scales and otherelectronic weighing devices.
◆Safe and anti-explosive product,can be used in atrocious environment and hazardous areas.
Important Features
◆Capacities:250lb to 20Klb and 0.25t to 5t.
◆High accuracy.
◆Strainless steel construction.
◆Low profile.
◆With OIML approval.
Outline Dimension mm(inch) :
Capacity | L | L1 | L2 | L3 | d | H | W | D | H1 | M |
250lb,500lb,
750lb,1Klb |
130 | 15.7 | 25.4 | 76.2 | 13.46 | 30.2 | 30.7 | 13.4 | 16 | M12-6H
1/2-20UNF-2B |
(5.12) | (0.62) | (1) | (3) | (0.53) | (1.19) | (1.2) | (0.53) | (0.63) | ||
0.5t,1t,2t
2.5K,3K, 4K,5KSE |
130
(5.12) |
15.7
(0.62) |
25.4
(1) |
76.2
(3) |
13.4
(0.52) |
31.23
(1.23) |
31.32
(1.23) |
13.4
(0.53) |
15.75
(0.62) |
M12-6H
1/2-20UNF-2B |
3t,5t
2.5KSE,5K, 7.5K,10K,15K |
171
(6.73) |
19
(0.75) |
38.1
(1.5) |
95.2
(3.75) |
20.65
(0.81) |
36.8
(1.45) |
36.8
(1.45) |
20.65
(0.81) |
17.78
(0.7) |
M20X2.5-6H
3/4-15UNF-2B |
20K | 222.25
(8.75) |
25.4
(1) |
50.8
(2) |
120.7
(4.75) |
26.9
(1.06) |
49.5
(1.95) |
49.5
(1.95) |
27.56
(1.08) |
24.78
(0.97) |
M24X2-6H
1-12UNF-2B |
Specifications:
Capacity | t | 0.1/0.15/0.2/0.25/0.3/0.4/0.5/0.75/1/1.5/2/3/5/7.5/10 | |||
lb | 250/500/750/1K/1.5K/2K/2.5K/2.5KLE/3K/4K/5K/5KSE/7.5K/10K/15K/20K | ||||
Accuracy | C2 | C3 | A5M | B10M | |
Approval | OIML R60 C3 | ||||
Maximum number of verification intervals | n max | 2000 | 3000 | 5000 | 10000 |
Minimum load cell verification interval | v min | Emax/5000 | Emax/10000 | Emax/15000 | Emax/10000 |
Combined error | (%FS) | ≤± 0.030 | ≤± 0.020 | ≤± 0.026 | ≤± 0.050 |
Creep | (%FS/30min) | ≤± 0.024 | ≤± 0.016 | ≤± 0.017 | ≤± 0.040 |
Temperature effect on sensitivity | (%FS/10℃) | ≤± 0.017 | ≤± 0.011 | ≤± 0.013 | ≤± 0.040 |
Temperature effect on zero | (%FS/10℃) | ≤± 0.023 | ≤± 0.015 | ≤± 0.014 | ≤± 0.020 |
Output sensitivity | (mv/v) | 3.0±0.008 | |||
Input resistance | (Ω) | 350±3.5 | |||
Output resistance | (Ω) | 350±3.5 | |||
Insulation resistance | (MΩ) | ≥ 5000(50VDC) | |||
Zero balance | (%FS) | 1 | |||
Temperature, compensated | (℃) | -10~+40 | |||
Temperature,allowed | (℃) | -35~+65 | |||
Excitation, Recommended | (V) | 5~12(DC) | |||
Excitation,Max | (V) | 18(DC) | |||
Safe overload | (%FS) | 150 | |||
Ultimate overload | (%FS) | 300 |