Troubleshooting:
1: Check whether the gate is energized (whether the rated voltage is 220 V)
2: Check if the intelligent controller is powered on
3: Check whether the control wire between the intelligent controller and the gate controller is connected normally (whether it is loose or broken)
4: When the railings can not fall down, check whether there are metal objects on the coil
5: Turn the device off and back on.
—Fault phenomenon: the infrared detector can not detect whether the vehicle is completely loaded.
Troubleshooting:
1: Check whether the intelligent controller is powered on (whether the rated voltage is 12V)
2: Check whether the infrared detector is powered on
3: Check whether there are objects blocking between the infrared detectors
4: Check whether the communication line can communicate normally
5: Check whether the receiver of the infrared detector receives the signal from the projector normally;
6: Check whether the communication line between the intelligent controller and the infrared detector is connected normally (whether it is loose or broken)
7: Turn the device off and back on.
—Fault phenomenon: the traffic light is not on
Troubleshooting:
1: Check whether the intelligent controller is powered on (whether the rated voltage is 220 V)
2: Check whether the traffic lights work normally
3: Check whether the equipment is powered on normally
4: Check whether the communication line between the intelligent controller and the traffic light is connected normally (whether it is loose or broken)
5: Turn the device off and back on.